Collection: Plastic Inspection Chambers

Plastic inspection chambers are lightweight polypropylene and polyethylene chambers for access to underground drains, light enough to handle without lifting gear. Pick the diameter for the depth, then the base to match your pipe: 110mm or 160mm sewer pipe, or twinwall.

Read the buying guide and questions
  • Polydrain 320mm and 450mm bases for 110mm pipe, and a 450mm base for 160mm
  • Risers with seals (215mm high on the 450mm); stack them to reach the depth you need
  • Complete kits with two risers and a round or square cover and frame
  • Accesso 450mm and 600mm adoptable one-piece chambers for sewer pipe
  • Accesso 600mm chambers for 150mm, 225mm and 300mm twinwall, with two side inlets

Other Inspection Chambers

1 category

See all Inspection ChambersCan't see what you need? Get a quote

Where chambers go

Put a chamber where pipes join, where the run changes direction, and at intervals along long straight runs, so every length can be reached for clearing and inspection. To work out how many a site needs, send your drawing for a free drawing take-off.

How to install

  1. Dig the pit a little wider than the chamber, down to the level of the pipes.
  2. Lay and compact a level bed of granular material such as pea shingle.
  3. Set the base on the bed, lined up with the incoming and outgoing pipes. Remove the blanking plugs only from the ports you are using.
  4. Lubricate the seals, connect the pipes and fit the risers. Add risers until the top is at the right height for the cover.
  5. Check the line and levels, then backfill evenly round the chamber with compacted material.
  6. Fit the frame and cover level with the finished surface.

Follow the maker's fitting guide for pit size, bedding and backfill.

Related ranges

Questions about plastic inspection chambers

How deep does a Polydrain kit go?

The complete 320mm kit reaches a 510mm invert depth and the 450mm kit 670mm. Add risers to go deeper.

Are plastic inspection chambers adoptable?

Some are. The Accesso 450mm and 600mm chambers for sewer pipe are sold for adoptable use; check the sewerage company's requirements for your site.

How far apart should inspection chambers be?

Fit one at every junction and change of direction, and at intervals along long straight runs. The maximum spacing depends on the rules for your site. In England, check your layout with Building Control, and for a sewer that will be adopted, follow the sewerage company's requirements. Wales, Scotland and Northern Ireland have their own rules.

Can a plastic inspection chamber go under a driveway?

It can, if the maker rates the chamber for that load. In a drive or traffic area, surround the top of the chamber with concrete so it cannot shift, and fit a cover and frame rated for the traffic. Check the maker's load limits before you order.