Our Harlequin oil storage tanks can be used for agricultural and industrial applications and are available in both vertical and horizontal form. Our tanks are available for smaller storage uses such as between 350 litres and 1000 litres and larger storage purposes which range between 350 litres and 54,000 litres. Our range includes, Bunded Oil Tanks, Waste Oil Storage, Slim line Oil Tanks and Single Skin Tanks. Our Single Skin tanks range from 650 litres to 2,500 litres.
-
Harlequin Vertical Single Skin Oil Tank 1,450 ltr
Capacity : 1406 litres/ 309 gallons
Width in mm: 1350
Length in mm: 1350
Height in mm: 1260
Weight in kg when empty: 45
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Low Profile Single Skin Oil Tank 1,200 ltr
Capacity : 1251 Litres / 275 Gallons
Length in mm: 1740
Width in mm: 1320
Height in mm: 825
Weight in kg when empty: 50
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Horizontal Single Skin Oil Tank 1,400 ltr
Capacity : 1380 litres/ 303 gallons
Width in mm: 1095
Length in mm: 1805
Height in mm: 1135
Weight in kg when empty: 55
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Slimline Single Skin Oil Tank 1,100 ltr
Capacity : 1040 Litres / 228 Gallons
Length in mm: 1650
Width in mm: 690
Height in mm: 1420
Weight in kg when empty: 60
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Horizontal Single Skin Oil Tank 1,650 ltr
Capacity : 1640 litres
Width in mm: 1165
Length in mm: 1850
Height in mm: 1215
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Vertical Single Skin Oil Tank 2,500 ltr
Capacity : 2450 litres
Width in mm: 1700
Length in mm: 1700
Height in mm: 1370
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Horizontal Single Skin Oil Tank 2,100 ltr
Capacity : 1994 litres
Width in mm: 1240
Length in mm: 2140
Height in mm: 1270
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Horizontal Single Skin Oil Tank 2,500 ltr
Capacity : 2497 litres
Width in mm: 1385
Length in mm: 2180
Height in mm: 1410
Outlet: 1″ BSP Female
Fill Point: 2″ BSP with cap & chain
Inspection Access: Yes
OFCERT: Yes
All oil tanks should be installed by a competent person in accordance with the OFTEC regulations, British Standards and LABC regulations.within 50m of a well, borehole or spring
- located over a hard surface where a spillage could enter controlled water
- in a position where the vent pipe outlet is not visable from the fill point
- within an Enviroment Agency source protection zone 1 (see www.environment-agency.gov.uk)
- or in close proximity to any other environmental hazard
- All commercial properties must have tanks with secondary containment if they store over 200 litres of oil (single skin tanks can be used as long as they are inside a masonry bund which is impervious to oil and contains 110% of the primary tanks capacity).
Quick View -
Harlequin Evo 650ITT Slimline Bunded Oil Tank (top outlet)
Length: 1,715mm
Width: 670mm
Height: 1,335mm
Weight: 105KG
Nominal Capacity: 645 litresThe 650ITE/ITT is supplied with the following features:
- Electronic oil monitor
- 32mm Gauge fitting point
- Bottom outlet fitting kit / Top outlet fitting kit
- 2″ fill point
- 4″ lockable inspection point
- Lockable manhole access
- 1″ BSP (F) outlet connection
- Vent
- LRC failsafe overfill prevention probe
- Anti-theft tank sticker, displaying the message ‘THIS TANK IS ALARMED!’
Quick View -
Harlequin Evo 650ITE Slimline Bunded Oil Tank (bottom outlet)
Length: 1,715mm
Width: 670mm
Height: 1,335mm
Weight: 105KG
Nominal Capacity: 645 litresThe 650ITE/ITT is supplied with the following features:
- Electronic oil monitor
- 32mm Gauge fitting point
- Bottom outlet fitting kit / Top outlet fitting kit
- 2″ fill point
- 4″ lockable inspection point
- Lockable manhole access
- 1″ BSP (F) outlet connection
- Vent
- LRC failsafe overfill prevention probe
- Anti-theft tank sticker, displaying the message ‘THIS TANK IS ALARMED!’
Quick View